Technical specifications
PRWH DC Power Board (for ZXA10 OLT)
Product Model: PRWH
Product Type: -48V DC Power Interface Board / Power Supply Module
Compatible Platforms: ZXA10 C300, C350, C320 OLT Chassis
1. Product Overview
The PRWH is a high-efficiency, carrier-grade DC power interface board designed for ZXA10 C300/C350/C320 OLT chassis. It provides stable -48V/-60V DC power input, power distribution, filtering, protection, and real-time monitoring for all service boards, control modules, and system components. Featuring a compact design, hot-swappable capability, and 1+1 power redundancy, it ensures reliable and uninterrupted power for FTTH, FTTB, and enterprise optical access networks.
2. Key Specifications
Electrical Parameters
- Input Voltage: -48V DC ~ -60V DC (telecom standard)
- Max Input Current: 40A (high-power capacity)
- Power Consumption (Self): 5W (low standby power)
- Input Interface: Standard DC power terminal (support for battery backup)
- Battery Interface: Integrated BAT+/BAT- terminals for external storage battery connection
- Temperature Sensor Interface: For battery temperature compensation (default 25°C without sensor)
Physical & Mechanical
- Dimensions (H × W × D): 197.75 × 25 × 225 mm
- Weight: 0.36 kg (ultra-lightweight)
- Mounting: Horizontal installation in OLT chassis slots
- C300/C350: Slots 11/12
- C320: Slots 0/1
- Cooling: Forced air cooling (chassis fan)
- Hot-Swappable: Yes (online replacement without service interruption)
Interfaces & Indicators
- PWR: Main DC power input interface
- COM/TST1: Debug/test RJ45 interface
- TST2: Reserved test interface
- LED Indicators:
- RUN (Green): Slow blink (normal operation); Solid (self-test OK); Off (power off/fault)
- ALM (Red): On (hardware fault); Slow blink (wrong slot/abnormality)
Protection Features
- Over-Voltage Protection (OVP)
- Under-Voltage Protection (UVP)
- Power Input Interruption Alarm & Protection
- Over-Current & Short-Circuit Protection
- Surge/Lightning Protection
- Reverse Polarity Protection
System Features
- Redundancy Mode: 1+1 power redundancy (dual PRWH boards)
- Load Balance: Automatic load sharing when dual inputs are equal
- Power Monitoring: Real-time voltage, current, power consumption detection
- Alarm Functions: Input abnormality, fault, and temperature alarms
- Control Interfaces: 2 × RJ45 reserved for management/test
Environmental Specifications
- Operating Temperature: -40°C ~ +65°C
- Storage Temperature: -40°C ~ +85°C
- Humidity: 5% ~ 95% (non-condensing)
- Altitude: Up to 4,000 m
3. Core Features
- High Power Density: 40A max current for high-capacity OLT deployments.
- Carrier-Grade Reliability: Full electrical protections, redundant design, and industrial-grade components.
- Smart Power Management: Real-time monitoring, alarm, and battery temperature compensation.
- Flexible Deployment: Compatible with ZXA10 C300/C350/C320 chassis.
- Easy Maintenance: Hot-swappable design for zero-downtime replacement.
- Compact & Lightweight: Space-saving horizontal installation, minimal chassis footprint.
- Low Power Loss: Only 5W self-consumption, high energy efficiency.
4. Typical Applications
- ZXA10 C300/C350/C320 OLT main power supply
- Central office (CO) fiber-optic access equipment
- FTTH/FTTB triple-play service networks
- Enterprise/campus high-density optical networks
- Carrier-grade redundant DC power systems
- Battery-backed telecom power environments