Technical specifications
PRAC AC Power Module (for ZXA10 OLT Series)
Product Model: PRAC
Product Type: AC Input Power Supply Module / Power Interface Board
Compatible Platforms: ZXA10 C600, C650, C680 OLT Chassis
1. Product Overview
The PRAC is a carrier-grade AC-DC power conversion module designed for ZXA10 C600/C650/C680 OLT chassis. It converts mains AC input to stable -48V/–60V DC power, providing reliable and efficient power distribution to all service boards and control modules. Featuring hot-swappable design, comprehensive protections, and smart monitoring, it ensures uninterrupted operation for FTTH/FTTB broadband and triple-play service environments.
2. Key Specifications
Electrical Parameters
- Input Voltage: 100–240V AC, auto-adaptive (50/60 Hz)
- Input Current: ≤ 16A (max)
- Output Voltage: -53.5V DC (nominal, telecom standard)
- Output Power: Max 350W
- Efficiency: ≥ 90% (typical at full load)
- Power Factor: ≥ 0.99 (active PFC)
- Ripple & Noise: ≤ 200mV (peak-to-peak)
Physical & Mechanical
- Dimensions (H×W×D): 23.9mm × 393.1mm × 214mm (1U slot)
- Weight: Approx. 1.25 kg
- Cooling: Forced air (chassis fan)
- Mounting: 19-inch rack, hot-swappable
Environment
- Operating Temperature: -40°C to +65°C
- Storage Temperature: -40°C to +85°C
- Humidity: 5%–95% (non-condensing)
- Altitude: Up to 4,000 m
Indicators & Controls
- LED Indicators:
- RUN (Green): Normal operation (blinking)
- ALM (Red): Fault/abnormality
- PWR (Green): Input power present
- Buttons: Power on/off, reset
- Interfaces: AC input terminal, battery backup port, RS485 monitoring port
Protection Features
- Over-voltage protection (OVP)
- Under-voltage protection (UVP)
- Over-current protection (OCP)
- Short-circuit protection (SCP)
- Over-temperature protection (OTP)
- Reverse polarity protection
- Lightning/surge protection (±6kV contact discharge)
Compatibility & Redundancy
- Chassis Support: ZXA10 C600, C650, C680
- Redundancy: 1+1 or 2+2 power redundancy support
- Hot-Swap: Yes, online replacement without service interruption
3. Core Features
- High-Efficiency Conversion: Active PFC and advanced topology ensure >90% efficiency, reducing energy consumption and heat.
- Wide Voltage Input: Universal 100–240V AC compatibility for global deployment.
- Carrier-Grade Reliability: Full electrical protections, redundant design, and industrial-grade components for 99.999% uptime.
- Hot-Swappable: Maintenance and replacement without powering down the OLT chassis.
- Smart Monitoring: Real-time voltage, current, temperature, and fault status via LED and SNMP/TR-069.
- Battery Backup: Integrated battery charging/discharging control for UPS/battery backup systems.
- EMI/EMC Compliance: Meets telecom EMC standards, minimizing interference with optical and data signals.
4. Typical Applications
- ZXA10 C600/C650/C680 OLT main power supply
- Central office (CO) fiber access equipment
- FTTH/FTTB/P2P broadband deployment
- Triple-play (Internet, VoIP, IPTV) service platforms
- Enterprise/campus optical networks
- Carrier-grade redundant power systems