Technical specifications
PRAM AC Power Module (for ZXA10 C320 OLT)
Product Model: PRAM
Product Type: AC-to-DC Power Supply Module / Power Interface Board
Compatible Platform: ZXA10 C320 Compact OLT Chassis

1. Product Overview
The PRAM is a carrier-grade, high-efficiency AC-DC power module designed exclusively for the ZXA10 C320 2U compact OLT. It converts universal 110V/220V AC mains power into a stabilized -48V DC output to power the entire OLT chassis, including control boards, service boards, and uplink modules. Featuring hot-swappable design, 1+1 power redundancy, and comprehensive protections, the PRAM ensures reliable, uninterrupted power for FTTH, FTTB, and enterprise access networks where standard DC power infrastructure is unavailable.
2. Key Specifications
Electrical Parameters
- Input Voltage: 100V–240V AC (auto-adaptive, single-phase)
- Input Frequency: 50/60 Hz (45–65 Hz tolerance)
- Output Voltage: -48V DC (nominal, adjustable -42V to -57V DC)
- Max Output Power: 320W
- Max Output Current: 6.7A (at -48V DC)
- Self Power Consumption: 13.2W (low idle power)
- Efficiency: >90% (at full load)
- Power Factor: ≥0.95 (active PFC)
Physical & Mechanical
- Dimensions (H × W × D): 200.25 × 37 × 225 mm
- Weight: 1.346 kg
- Mounting: Horizontal installation in C320 slots 0/1
- Cooling: Forced air cooling (chassis fan)
- Hot-Swappable: Yes (online replacement)
Interfaces & Ports
- AC Input: 1 × IEC C14 AC power socket
- Battery Interface: 1 × DC terminal block (for backup battery)
- Temperature Sensor: 1 × interface for battery temp compensation
- COM/DEBUG: 1 × RJ45 (RS-232)
LED Indicators
- RUN (Green): Slow blink = normal; Solid = self-test OK; Off = fault
- ALM (Red): On = hardware fault; Blink = abnormal status
- PWR (Green): AC input & DC output normal
Protection Features
- Over-Voltage Protection (OVP)
- Under-Voltage Protection (UVP)
- Over-Current & Short-Circuit Protection
- Over-Temperature Protection (OTP)
- Surge/Lightning Protection (±6kV)
- Reverse Polarity Protection
- EMI Filtering & EMC Compliance
System Features
- Redundancy: 1+1 power redundancy (dual PRAM boards)
- Load Balance: Automatic load sharing (dual inputs)
- Battery Management: Charging/discharging control
- Real-Time Monitoring: Voltage, current, temp detection
- Alarm: Input/output fault, over-temperature alarms
Environmental Specifications
- Operating Temperature: -40°C ~ +65°C
- Storage Temperature: -40°C ~ +85°C
- Humidity: 5% ~ 95% (non-condensing)
- Altitude: Up to 4,000 m
- EMC: Complies with IEC 61000-3-2, telecom standards
3. Core Features
- Universal AC Input: 100–240V AC for global deployment.
- High-Efficiency Conversion: >90% efficiency, low heat, energy-saving.
- Active PFC: Power factor ≥0.95, reduces grid harmonics.
- Carrier-Grade Reliability: Full protections, redundant design, 99.999% uptime.
- Hot-Swappable: Maintenance without OLT shutdown.
- Battery Backup Support: Integrated charge/discharge management.
- Compact & Lightweight: Fits 2U C320 chassis, space-saving.
- Smart Monitoring: Real-time telemetry & fault alarms.
- Wide Temp Range: Operates in extreme environments (-40°C to +65°C).
4. Typical Applications
- ZXA10 C320 OLT main power supply
- FTTH/FTTB triple-play networks
- Remote cabinets & outdoor OLT deployments
- Enterprise/campus fiber access
- Sites without -48V DC power infrastructure
- Battery-backed AC-powered telecom sites