1. Product Overview

The PRAM is a carrier-grade, high-efficiency AC-DC power module designed exclusively for the ZXA10 C320 2U compact OLT. It converts universal 110V/220V AC mains power into a stabilized -48V DC output to power the entire OLT chassis, including control boards, service boards, and uplink modules. Featuring hot-swappable design, 1+1 power redundancy, and comprehensive protections, the PRAM ensures reliable, uninterrupted power for FTTH, FTTB, and enterprise access networks where standard DC power infrastructure is unavailable.

 


 

2. Key Specifications

Electrical Parameters

  • Input Voltage: 100V–240V AC (auto-adaptive, single-phase)
  • Input Frequency: 50/60 Hz (45–65 Hz tolerance)
  • Output Voltage: -48V DC (nominal, adjustable -42V to -57V DC)
  • Max Output Power: 320W
  • Max Output Current: 6.7A (at -48V DC)
  • Self Power Consumption: 13.2W (low idle power)
  • Efficiency: >90% (at full load)
  • Power Factor: ≥0.95 (active PFC)

Physical & Mechanical

  • Dimensions (H × W × D): 200.25 × 37 × 225 mm
  • Weight: 1.346 kg
  • Mounting: Horizontal installation in C320 slots 0/1
  • Cooling: Forced air cooling (chassis fan)
  • Hot-Swappable: Yes (online replacement)

Interfaces & Ports

  • AC Input: 1 × IEC C14 AC power socket
  • Battery Interface: 1 × DC terminal block (for backup battery)
  • Temperature Sensor: 1 × interface for battery temp compensation
  • COM/DEBUG: 1 × RJ45 (RS-232)

LED Indicators

  • RUN (Green): Slow blink = normal; Solid = self-test OK; Off = fault
  • ALM (Red): On = hardware fault; Blink = abnormal status
  • PWR (Green): AC input & DC output normal

Protection Features

  • Over-Voltage Protection (OVP)
  • Under-Voltage Protection (UVP)
  • Over-Current & Short-Circuit Protection
  • Over-Temperature Protection (OTP)
  • Surge/Lightning Protection (±6kV)
  • Reverse Polarity Protection
  • EMI Filtering & EMC Compliance

System Features

  • Redundancy: 1+1 power redundancy (dual PRAM boards)
  • Load Balance: Automatic load sharing (dual inputs)
  • Battery Management: Charging/discharging control
  • Real-Time Monitoring: Voltage, current, temp detection
  • Alarm: Input/output fault, over-temperature alarms

Environmental Specifications

  • Operating Temperature: -40°C ~ +65°C
  • Storage Temperature: -40°C ~ +85°C
  • Humidity: 5% ~ 95% (non-condensing)
  • Altitude: Up to 4,000 m
  • EMC: Complies with IEC 61000-3-2, telecom standards

 


 

3. Core Features

  • Universal AC Input: 100–240V AC for global deployment.
  • High-Efficiency Conversion: >90% efficiency, low heat, energy-saving.
  • Active PFC: Power factor ≥0.95, reduces grid harmonics.
  • Carrier-Grade Reliability: Full protections, redundant design, 99.999% uptime.
  • Hot-Swappable: Maintenance without OLT shutdown.
  • Battery Backup Support: Integrated charge/discharge management.
  • Compact & Lightweight: Fits 2U C320 chassis, space-saving.
  • Smart Monitoring: Real-time telemetry & fault alarms.
  • Wide Temp Range: Operates in extreme environments (-40°C to +65°C).

 


 

4. Typical Applications

  • ZXA10 C320 OLT main power supply
  • FTTH/FTTB triple-play networks
  • Remote cabinets & outdoor OLT deployments
  • Enterprise/campus fiber access
  • Sites without -48V DC power infrastructure
  • Battery-backed AC-powered telecom sites

 

Please leave for us your contact information

This site uses cookies

We use cookies to collect information about how you use this site. We use this information to make the website work as well as possible and improve our services.more details

WhatsApp us